品牌 : | Simpson | 型號 : | Simpson228 |
加工定制 : | 否 | 類型 : | 指針式電流測量儀表 |
測量范圍 : | 標準 | 準確度 : | 0.1 |
功率 : | 10 | 電源電壓 : | 220 |
外形尺寸 : | 300 | 產地 : | 美國 |
是否進口 : | 否 | 規格 : | 標準 |
適用范圍 : | 泄漏電流測試 | 主要下游平臺 : | 進貨 |
主要銷售地區 : | 全球 | 是否跨境貨源 : | 是 |
Simpson228泄漏電流表
Simpson228 AC/DC泄漏電流表產品簡介
Simpson228 AC/DC泄漏電流表主要測試AC/DC泄漏電流,設計符合 新的UL、IEC和ANSI規格。Simpson228查出當前AC和DC漏出并且模仿人的反應在三個不同水平?--?反應,放棄,以及灼傷危險。每個Simpson228具有彈簧夾、指南和電池以及測試筆。
查出危險AC & DC?泄漏電流在電子或電子設備導電性表面
設計遇見新的IEC、ANSI和UL指南
反應,放棄和無重負的 危險網絡測量
電池操作為 輕便
Detail | ||||||
General | ReactionResponse Network | Let-GoResponse Network | Unweighted Burn Hazard Response Network | |||
Equivalent network component values: | Complies with values specified in IEC 990 (excluding fuse) | |||||
Equivalent measuring instrument load: | 1 M - 10pF | 1 M - 62 pF | 1 M- 1 pF | |||
Ranges | 0.3, 1, 3, 10 M.I.U. | 0.3, 1, 3, 10 M.I.U. | 0-100 mA RMS | |||
Current accuracy: | ±2 F.S. @ 60 Hz | |||||
Meter measurement method: | True RMS | |||||
Meter frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) | |||||
DC to 1 Hz | Pointer shall track within 5 of peak | |||||
2Hz to 19Hz (Accuracy not supported) | ? | |||||
20 Hz to 200 KHz | ±2 F.S. | ±2.5 of F.S. | ±2 F.S. | |||
200 KHz to 1 MHz | ±2 F.S. | ±2.5? F.S | ±5 F.S. | |||
Output sensitivity: | Full scale meter indication equals 1V RMS (Measured with a 1 M, 12 pF load) | |||||
Output accuracy: | ±2 of reading @ 60 Hz | |||||
Output frequency response: | (Relative to ANSI C101-1992 or UL-1459 2nd edition) | |||||
DC to 50Hz | ±2 of reading | |||||
50 Hz to 100 KHz | ±2.5 of reading | ±2 /-3 of reading | ±2 of reading | |||
100 kHz to 1 MHz | ±5 of reading | |||||
Voltmeter range: | 0-300 V (AC or DC) | |||||
Voltmeter accuracy:DC to 1 Hz | Pointer shall track within 5 of peak | |||||
2Hz to 19Hz (Accuracy not supported) | ? | |||||
20 Hz to 1KHz | 3 F.S. @ 60 Hz (Add1 for every additional 100Hz) | |||||
Voltmeter frequency response: | DC to 1 KHz | |||||
Power requirements | (2) 9V (NEDA 1604A) batteries | |||||
Physical | 7" x 5.25" x 3.125", 2-1/2 lbs (1.4kg), ABS plastic, fused input | |||||
Environmental | 27°C2° C, 70 non condensing relative humidity. Outside this range derate by 10 per °C | |||||
Maximum operating range | 0° to 40° C |